Radiometer für Bestrahlungsstärke im Spektralbereich von 250 nm bis 1700 nm.
Modell | Foto | Spektrale Wirkungsfunktion | Spektralbereich / nm | Typ. Min. Messbereich | Typ. Max. Messbereich | Kosinus Diffusor | Bemerkungen |
---|---|---|---|---|---|---|---|
![]() |
UV-A | 320 - 400 nm | 0.7 mW/m² | 14 kW/m² | 11 mm Ø | ||
![]() |
UV-A | 315 - 400 nm | 1.3 mW/m² | 25 kW/m² | 11 mm Ø | ||
![]() |
UV-B | 280 - 315 nm | 3 mW/m² | 29 kW/m² | 11 mm Ø | ||
![]() |
UV-C | 250 - 280 nm | 2.5 mW/m² | 25 kW/m² | 11 mm Ø | ||
![]() |
Schmalband UV-C | 254 nm | 2.5 mW/m² | 25 kW/m² | 11 mm Ø | ||
![]() |
Breitband UV | 250 - 400 nm | 2.6 mW/m² | 52 kW/m² | 11 mm Ø | ||
![]() |
UV-GI | 254 nm | 2.5 mW/m² | 25 kW/m² | 8 mm Ø | ||
![]() |
Vis | 400 - 800 nm | 3.3 mW/m² | 667 kW/m² | 11 mm Ø | ||
![]() |
Vis-NIR | 400 - 1000nm | 0.5 mW/m² | 100 kW/m² | 11 mm Ø | ||
![]() |
Vis | 400 - 800 nm | 3.3 mW/m² | 667 kW/m² | 11 mm Ø | ||
![]() |
NIR | 800 - 1000 nm | 0.13 mW/m² | 25 kW/m² | 11 mm Ø | ||
![]() |
Verlängert NIR | 950 - 1700 nm | 0.13 mW/m² | 25 kW/m² | 11 mm Ø |
Radiometer für den Strahlungsfluss (W).
Modell | Foto | Spektralbereich / nm | Typ. Min. Messbereich | Typ. Max. Messbereich | Eingangsoptik | Bemerkungen |
---|---|---|---|---|---|---|
![]() |
400 -1100nm | 4.4 nW | 800 mW (*1) | Kugel 50 mm Ø port 12.7 mm Ø | ||
![]() |
400 -1100nm | 4.4 nW | 800 mW (*1) | Kugel 50 mm Ø port 12.7 mm Ø | ||
![]() |
400 -1100nm | 7.8nW @630nm 5.6nW @900nm | 1.56W @630nm 1.13W @900nm | Kugel 30mmØ port 5mmØ | ||
X1 + ISD-3P-IGA |
![]() |
800-1800 nm | 0.29µW @1300nm 0.25µW @1550nm | 5.9W @1300nm 5.0W @1550nm | Kugel 30mmØ port 5mmØ | |
![]() |
400-1100nm | 2.0 nW @630nm | 400 mW @630nm | Kugel 50 mmØ port 10 mmØ | ||
X1 + ISD-5P-IGA |
![]() |
800-1800 nm | Kugel 50 mmØ port 10 mmØ | |||
![]() |
800-1800 nm | Kugel 30mmØ port 5mmØ | ||||
![]() |
400-1100nm | 2.0 nW @630nm | 400 mW @630nm | Kugel 50 mmØ port 10 mmØ | ||
P-9710-2 + ISD-5P-IGA |
![]() |
800-1800 nm | Kugel 50 mmØ port 10 mmØ | |||
![]() |
400-1100nm | 3.1nW @630nm 2.6nW @900nm | 0.6W @630nm 0.5W @900nm | Kugel 100mmØ port 15mmØ | ||
![]() |
400 -1100nm | 83nW @630nm 71nW @900nm | 16W @630nm 14W @900nm | Kugel 150 mmØ port 38.1 mmØ | ||
![]() |
400-1100nm | 25nW @630nm 20nW @900nm | 5W @630nm 4W @900nm | Kugel 300mmØ port 100mmØ | ||
![]() |
400 -1800 nm | 25nW @630nm 20nW @900nm 200nW @1300nm 280nW @1550nm | 4W @630nm 5W @900nm 40W @1300nm 55W @1550nm | Kugel 300mmØ port 100mmØ | ||
P-9710-4 + ISD-1.6-SP-Vxx |
![]() |
400-1100nm | 0.73µW @630nm 0.66µW @900nm | 14.6W @630nm 13.3W @900nm | Kugel 16mmØ port 5mmØ | Optionales Oszilloskop für Pulsform |
(*1) Max CW eventuell begrenzt durch max. Betriebstemperatur
Siehe auch: Spektralradiometer mit Ulbrichtkugel