Quick-Contact

Gigahertz Optik GmbH (Headquarter)
Phone: +49 (0)8193-93700-0
info@gigahertz-optik.de

Gigahertz-Optik, Inc. (US office)
Phone: +1-978-462-1818
info-us@gigahertz-optik.com

Wishlist

You can add products to the wish list and compare them with one another or send us an inquiry. There are wish list symbols on product pages and product tables for this purpose.

This Product is discontinued, please contact us if you are still interested.

ISD-100HFT-BTS2048-VL

System for the luminous flux and light color measurement of individual 2π and 4π light light sources. Features: Turnable Integrating sphere with 100cm diameter, auxiliary lamp and a hemispherical shell for opening and closing, compact spectral light meter with Bi-Tec sensor for acurate measurement of the luminous flux, spectral radiant power, CCT, CRI, chromaticity coordinates, etc.

ISD-100HFT-BTS2048-VL

The lamp position influences the luminous flux

LED lamps are often manufactured with integral driver circuitry. This means that the lamp orientation (base up, base down, etc) can have a significant effect on the junction temperature of the LEDs due to the different heat flow scenarios. Luminous flux, spectrum and color are directly related to junction temperature. The lifetime of LEDs is also reduced as junction temperature is increased. The measurement of photometric properties of LED lamps operating in the different orientations is therefore highly recommended. The ISD-100HFT-BTS2048-VL light meter from Gigahertz-Optik is a high-quality, CCD-based spectroradiometer with a rotatable, 100cm diameter, integrating sphere. This combination can be used to measure the luminous flux, spectrum, color, and color rendering index of LED lamps operating in any orientation.


The BTS256-VL light meter

The high-quality BTS2048-VL CCD based spectroradiometer is internationally recognized as a high-end product. It is one of the most compact spectroradiometers on the market which enables direct system integration in many applications without the need for expensive, and potentially measurement degrading, light guides. Among its characteristic features is its diffusor window with cosine corrected field of view for the measurement of spectral irradiance and spectral illuminance. This also permits direct mounting onto integrating spheres (e.g. the ISD-100HFT) for measurement of luminous flux. More detailed information about the BTS2048-VL can be found in the respective data sheets. The unit is also available in the BTS2048-VL-TEC thermoelectric cooled version.


Enhancement of the BTS2048-VL with the ISD-100HFT-V03 and ISD-100-V04 integrating spheres

One unique feature of the ISD-100HFT-V03 is that it can be rotated around its frame. This allows for operation of LED lamps in upright (lamp base down), lying (lamp base horizontal) and hanging (lamp base up) positions. The sphere has a diameter of 100 cm and one of its hemispheres can be opened to allow easy access to the sample holder. The height of the sample holder can be adjusted for perfect positioning of the LED lamp at the center of the sphere. In order to operate 2Pi lamps outside the integrating sphere, the ISD-100HFT-V04 version has an extra measurement port with a 254 mm (10 inch) diameter. This remains closed when not in use. Both variants are equipped with an auxiliary lamp.


Calibration

One essential quality feature of photometric devices is their precise and traceable calibration. The ISD-100-HFT-BTS2048-VL is calibrated at Gigahertz-Optik’s DAkkS-accredited (D-K-15047-01-00) calibration laboratory for the spectral responsivity and spectral irradiance according to ISO/IEC 17025. Calibration for the luminous flux is performed using a BN-LHSF-104 calibration lamp placed at the center of the sphere. Spheres with an additional measurement port require additional calibration using a BN-LHSF-2P-20 calibration lamp that has 2pi radiation characteristics. Every device version comes with its respective calibration certificate.

The BTS2048-VL high-quality CCD sensor spectroradiometer with the rotatable ISD-100HFT integrating sphere

The BTS2048-VL high-quality CCD sensor spectroradiometer with the rotatable ISD-100HFT integrating sphere

The position of the lamp can be changed simply by rotating the sphere.

The position of the lamp can be changed simply by rotating the sphere.

BTS2048-VL high end CCD spectroradiometer for cw and flash measurements.

BTS2048-VL high end CCD spectroradiometer for cw and flash measurements.

S-BTS2048 user software interface

S-BTS2048 user software interface

CIE 1931 with binning fields

CIE 1931 with binning fields

Similar Products

ISD-100HF-BTS256-LED
System for the luminous flux measurement of 2π and 4π light fixtures inside a sphere. Features: Integrating sphere with a 1000 mm diameter, hemispherical shell for opening and closing, auxiliary lamp. Light meter for acurate measurement of luminous flux, spectral radiant power, CCT, CRI, chromaticity coordinates, User software, etc. Options: quadripole test sockets.
ISD-100HF-BTS2048-VL
System for the luminous flux and light color measurement of individual 2π and 4π light light sources. Features: Integrating sphere with 100cm diameter, auxiliary lamp and a hemispherical shell for opening and closing, compact spectral light meter with Bi-Tec sensor for acurate measurement of the luminous flux, spectral radiant power, CCT, CRI, chromaticity coordinates, etc.